Weekly Report 19Nov2010 26Nov2010
From RHESSI Wiki
Contents |
Pixon Albedo Imaging
Using Eduard Kontar's simulated eventlist files, Pixon Images were created for a compact circular gaussian source with an albedo contribution near disk center, and near the limb. The following parameters were used for each image:
- Time: 2-Sep-2002 00:07:36 - 00:08:16
- Energy 24keV - 51keV
- Detectors 1 to 4
- Image Size: 64 by 64 pixels
- Pixel Size: .5 arcsec by .5 arcsec
The following plots are extensions of the plots from the previous report.
The plot below shows the gaussian model of the compact source (orange),the original data map with the minimum and maximum value at each radial distance (Black), the Pixon image with the minimum and maximum value at each radial distance (Purple), and the clean image with the minimum and maximum value at each radial distance (Cyan)for a source near disk center.
The gaussian model falls off as we would expect the flux to fall in a circular gaussian. For 2 arcsec the model and the map are consistent, after this point the model falls off much more sharply, while the map shows a falloff that is not gaussian. The pixon image shows a tight envelope around the compact source, as does the clean image. As we move into the region where the albedo is present clean falls off in the same manner as the original map. The envelope around the the average of the flux for clean widens immediately after the compact source but then remains relatively constant. The pixon image immediately goes from a tight envelope around the compact source to a wider envelope in the region of the albedo. The size of the envelope remains constant radially but the average moves up and down in an unpredictable manner. For instance at approximately 3.5 arcsec from the peak of the compact source pixon images what appears to be a 'pileup' of flux. At the edges of the image the flux does not drop away to zero but seems to level off.
The plot below shows the gaussian model of the compact source (orange),the original data map with the minimum and maximum value at each radial distance (Black), the Pixon image with the minimum and maximum value at each radial distance (Purple), and the clean image with the minimum and maximum value at each radial distance (Cyan) for a source near the limb.
In the case of the source near the limb the averages of each the original data, the clean image, and the pixon image fall off in a similar manner to the averages near the disk center. There is more variation at any given point with the average moving up and down, but the trend is similar.