From RHESSI Wiki
This page contains information about changes/issues for RHESSI detector 6 after the 2014 anneal. Detector updates from 2012-mid 2014 can be found here: Detector 6 anneal 2012
Notes
After the 2014 anneal, detector 6 began its reincarnated life as an unsegmented detector but segmented shortly after (see below).
- On 2014 August 14, the HV on D6 was raised to 4926V in an attempt to segment it. This was successful, and D6 now operates as a segmented detector. Since its segmentation is borderline as of Aug/Sept 2014, it commonly unsegments during and just after the SAA.
D6 front slow LLD threshold history
post 2014 anneal | 0x0C (after segmentation)
|
D6 front fast LLD threshold history
post 2014 anneal | 0x22 (after segmentation)
|
D6 rear slow LLD threshold history
post 2014 anneal | 0x30 (after segmentation)
|
D6 rear fast LLD threshold history
post 2014 anneal | 0x45 (after segmentation)
|
D6 HV history
post 2014 anneal | 4510 V (unsegmented)
|
2014-Aug-14 03:40 UTC | 4926 V (was 4510 V) (segmented)
|